TFS20-LMiniaturized Single-Point LiDAR
TFS20-L is an approximately 1.35 g unenclosed single-point module for payload-critical ranging where the host provides mounting and environmental protection.
Light Weight
Compact Design
Strong Resistance To Ambient Light
Key specifications
- Measuring range
- 0.2 ~ 20 m
- Frame rate
- 0 / 20 / 50 / 100 / 250 Hz
- Interface
- UART,I²C
- Protection
- without enclosure
Need help confirming a selection or purchase details?
Applications


Robot Fall Prevention & Obstacle Avoidance

Smart Trigger
Full specifications
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Measuring range | 0.2 ~ 20 m | Detecting accuracy | ± 6 cm (0.2 ~ 6 m), 1% (≥ 6 m) |
| Frame rate | 0 / 20 / 50 / 100 / 250 Hz | Interface | UART,I²C |
| Protection | without enclosure | Dimensions | 21 mm × 15 mm × 7.87 mm |
| Power consumption | ≤ 0.43 W | Weight | ~ 1.35 g |
| Field of view | < 2° | Output data | Single-point Distance Value |
| Operating voltage | DC 3.3 ± 9% V |
Applicable scope and usage limits
Applicable scenarios
- Evaluate TFS20-L when a micro-UAV or compact device is sensitive to a few grams and needs more directional range than common short-range modules.
- The approximately 1.35 g module suits host-provided mounting and protection.
Conditions
- Confirm the 3.3 V supply, UART/I²C and optical window.
- Validate usable distance and control margin with dark ground, strong light, attitude changes and motion speed.
Not applicable scenarios
- For a sensor with its own protective enclosure or native industrial buses, compare TFmini Plus, TF02-Pro or the relevant industrial-interface model.
- For surrounding contours or complete obstacle coverage, evaluate 2D/3D sensing rather than only adding single-point range.
Short/mid-range sensing: payload, enclosure and cleaning
Filter by real working distance first, then assess host protection, industrial interfaces and window deposits. More range, an enclosure and automatic cleaning address different needs rather than one performance ranking.
View comparison topicCritical payload limits with host-provided protection
The approximately 1.35 g TFS20-L suits directional ranging on very small platforms where weight and space dominate.
Boundary: The module has no enclosure. Provide host protection and verify working distance on actual targets and in strong light.
View model detailsShort real distances with compact IP65 protection
Compare TFmini Plus when the task is short-range, about 12 g is acceptable and UART/I²C/I/O fits the controller.
Boundary: Its inclusion here does not make it a 40 m or 50 m candidate. Dusty level-sensing tasks also require window-maintenance comparison.
View model detailsMore distance without an automatic-cleaning requirement
Compare TF02-Pro for more directional range than short-range modules, board interfaces and an IP65 enclosure.
Boundary: For native CAN/RS-485, compare industrial-interface models. For recurring window deposits, compare a self-cleaning model.
View model detailsOne material-level point with recurring window deposits
For bins and silos, the selection reason is an integrated cleaning brush and suitable industrial integration to reduce manual window cleaning.
Boundary: Without a cleaning need, weigh the added mass and power. One height is not pile volume, and IP5X does not specify water protection.
View model details| Parameter | TFS20-L | TFmini Plus | TF02-Pro | TF02-Pro-W |
|---|---|---|---|---|
| Measuring range | 0.2 ~ 20 m | 0.1 ~ 12 m | 0.1 ~ 40 m | 0.1 ~ 25 m |
| Detecting accuracy | ± 6 cm (0.2 ~ 6 m), 1% (≥ 6 m) | ± 5 cm @ (0.1 ~ 5 m)± 1% @ (5 ~ 12 m) | ± 5 cm @ (0.1 ~5 m) ± 1% @(5 ~ 40 m) | ± 6 cm @ (0.1 ~ 6 m) ± 1% @ (6 ~ 25 m) |
| Frame rate | 0 / 20 / 50 / 100 / 250 Hz | 1 ~ 1000 Hz | 1 ~ 1000 Hz | 1 ~ 1000 Hz |
| Interface | UART,I²C | UART,I/O,I²C | UART,I/O,I²C | UART、I²C |
| Protection | without enclosure | IP65 | IP65 | IP5X |
| Dimensions | 21 mm × 15 mm × 7.87 mm | 35 mm × 18.5 mm × 21 mm | 69 mm × 41.5 mm × 26 mm | 85 mm × 59 mm × 43 mm |
| Power consumption | ≤ 0.43 W | 550 mW | ≤ 1 W | ≤ 2 W |
| Weight | ~ 1.35 g | 12 ± 1 g | 50 g | 90 ~ 92 g |
| Field of view | < 2° | 3.6° | 3° | 3° |
| Operating voltage | DC 3.3 ± 9% V | 5 ± 0.5 V | 5 ~ 12 V | DC 7 ~ 30 V |
FAQ
What is the measurement range of the TFS20-L?
The TFS20-L achieves a maximum range of 20 m at 90% reflectivity under low ambient light (0 Klux), dropping to 15 m in bright sunlight (100 Klux). For low-reflectivity targets (10%), the range is 12 m at 0 Klux and 9 m at 100 Klux. Minimum detectable distance is 0.2 m across all conditions.
What communication interfaces does the TFS20-L support?
The TFS20-L supports two communication protocols: UART at 115200 baud (8 data bits, 1 stop bit, no parity) and I²C at up to 400 kbps with slave-mode operation. The I²C default address is 0x10, configurable within the range 0x10–0x7F. Both use 3.3V LVTTL logic levels for direct microcontroller interfacing.
Which tasks suit TFS20-L, and why choose it?
Evaluate TFS20-L when a micro-UAV or compact device is sensitive to a few grams and needs more directional range than common short-range modules. The approximately 1.35 g module suits host-provided mounting and protection.
What are the accuracy and precision specifications?
The TFS20-L delivers ±60 mm (±6 cm) accuracy at 0.2–6 m range, improving to ±1% accuracy beyond 6 m. Precision (1σ repeatability) is 2 cm across the 0.2–6 m range. These specifications assume 25°C indoor conditions and 90% target reflectivity; environmental variation may degrade performance.
What are the operating temperature range and environmental ratings?
The TFS20-L operates from –20°C to +60°C with storage capability to –40°C to +85°C. It resists ambient light up to 100 Klux (equivalent to direct sunlight). However, the datasheet specifies 'N/A' for IP protection rating, meaning no sealed enclosure—not rated for dust or water ingress. Suitable for indoor or sheltered outdoor use only.
What power supply does the TFS20-L require?
The TFS20-L requires DC 3.3 V ±9% (operating range 3.0–3.6 V) with average power consumption ≤0.43 W. Peak current during transmission is 130 mA at 3.3 V. This low power budget makes it compatible with standard 3.3V microcontroller supplies (Arduino, STM32, Raspberry Pi) without dedicated regulators.
What are the physical dimensions and weight?
The TFS20-L measures 21×15×7.87 mm and weighs approximately 1.35 g. It terminates with a 0.8 mm 6-pin connector (Model WF08006-01207), enabling easy integration into compact UAVs, robotic platforms, and handheld devices with minimal mechanical footprint and weight penalty.
When should an alternative to TFS20-L be considered?
For a sensor with its own protective enclosure or native industrial buses, compare TFmini Plus, TF02-Pro or the relevant industrial-interface model. For surrounding contours or complete obstacle coverage, evaluate 2D/3D sensing rather than only adding single-point range. Confirm the 3.3 V supply, UART/I²C and optical window. Validate usable distance and control margin with dark ground, strong light, attitude changes and motion speed. If the project requires functional-safety certification, verify the corresponding evidence separately; Class 1 laser eye safety is not functional-safety certification.
How should TFS20-L be compared with other models or sensing approaches?
TFS20-L is selected primarily for very low mass. TFmini-S and TFmini Plus offer IP65; TF02-Pro offers more specified range and a higher update rate, with different weight and supply requirements. First decide whether the platform can provide its own protection.
What systems can the TFS20-L integrate with?
The TFS20-L is compatible with Arduino, Raspberry Pi, STM32, ESP32, and other 3.3V microcontroller platforms via UART (115200 baud) or I²C (400 kbps) interfaces. It integrates with ROS via standard sensor drivers and autopilot systems like Pixhawk for altitude hold and obstacle avoidance through serial telemetry. PLC systems can interface via RS485 converters using the UART port.