| TF-Luna | - Output data
- Single-point Distance Value
- Measuring range
- 0.2 ~ 8 m
- Interface
- UART,I/O,I²C
- Protection
- Without enclosure; external environmental protection required
| For lightweight UAVs with tight payload and mounting budgets when the measured ground distance is in the short-range envelope; validate target reflectivity and ambient light first. | Range and accuracy depend on target reflectivity, ambient light, and mounting attitude; do not extrapolate the short-range specification into unvalidated long-range altitude or safety control. | View product → |
|---|
| TFmini-S | - Output data
- Single-point Distance Value
- Measuring range
- 0.1 ~ 12 m
- Interface
- UART,I/O,I²C
- Operating voltage
- 5 ± 0.1 V
| Compare the approximately 5 g TFmini-S for light directional input in near-ground following with UART, I²C or I/O flight controllers. | IP65 follows Benewake's official catalog and Chinese manual. Validate dark ground, tilt, speed and mounting windows. One range is insufficient for complete terrain contours. | View product → |
|---|
| TFS20-L | - Output data
- Single-point Distance Value
- Measuring range
- 0.2 ~ 20 m
- Interface
- UART,I²C
- Protection
- without enclosure
| For payload-sensitive UAVs that need a 20 m-class standard-target range; the module is about 1.35 g and supports UART and I²C. | The module has no enclosure, and low reflectivity or strong ambient light reduces usable range. Validate interface, driver, and protection on the target flight stack and airframe. | View product → |
|---|
| TFA170-L | - Output data
- Single-point Distance Value
- Measuring range
- 0.1 ~ 170 m
- Interface
- RS-232
- Protection
- without enclosure
| For UAV missions that need longer ranging while controlling payload; official material specifies an approximately 10 g module with RS-232. | The module has no enclosure and requires 12 V. The product page and datasheet describe output rate differently, so verify the delivered hardware and document revision before integration. | View product → |
|---|
| TF02-Pro | - Output data
- Single-point Distance Value
- Measuring range
- 0.1 ~ 40 m
- Interface
- UART,I/O,I²C
- Protection
- IP65
| For UAV missions that need mid-range altitude input, IP65 protection, and a higher-rate distance signal while the payload and power budget can support it. | The 40 m-class rating depends on target reflectivity and ambient light; verify interface, firmware, power, and airframe mounting, and do not treat the maximum specification as a vehicle safety guarantee. | View product → |
|---|
| TF03 | - Output data
- Single-point Distance Value
- Measuring range
- 0.1 ~ 180 m
- Interface
- UART,CAN,RS-232,RS-485
- Protection
- IP67
| For outdoor UAV missions that need long range, an IP67 enclosure, multiple interfaces, and can accept a higher sensor mass. | Include the approximately 86 g mass and larger installation envelope in payload evaluation. Confirm the exact interface variant and usable range on real surfaces and environments. | View product → |
|---|