TF350Ultra Long Range Single-point LiDAR
Long Range
High Frequency
Strong Resistance To Ambient Light
IP65/IP67
Dedicated FoV
Key specifications
- Measuring range
- 0.2 ~ 350 m
- Frame rate
- 1 ~ 9800 Hz
- Interface
- UART,CAN,RS-232,RS-485
- Protection
- IP67
Need help confirming a selection or purchase details?
Applications


Level Detection

Security Warning
Full specifications
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Measuring range | 0.2 ~ 350 m | Detecting accuracy | ± 10 cm (≤ 10 m)1% (> 10 m) |
| Frame rate | 1 ~ 9800 Hz | Interface | UART,CAN,RS-232,RS-485 |
| Protection | IP67 | Dimensions | 78 mm × 67 mm × 40 mm |
| Power consumption | ≤ 1 W | Weight | 224 ± 3 g |
| Field of view | 0.35° | Output data | Single-point Distance Value |
| Operating voltage | 5 ~ 24 V |
Applicable scope and usage limits
Applicable scenarios
- Evaluate TF350 when industrial equipment must observe a distant target and benefits from an IP67 enclosure and compatible interfaces.
- It supplies directional spacing, trigger or long-range warning data.
Conditions
- Include approximately 224 g and the narrow field in mounting design.
- Validate usable distance with target size, reflectivity, aiming stability and actual weather.
Not applicable scenarios
- For shorter real working distances, compare lighter TF03 or TF02-Pro models.
- Micro-UAVs and compact gimbals should also compare lightweight modules by payload cost.
- More single-point range does not replace scanning or 3D coverage.
Long-range single-point sensing: payload, interfaces and feedback speed
Define target size, working distance and required valid-range interval before comparing payload, enclosure and interfaces. Directional range feeds flight-control, focus or positioning algorithms; it is not a 3D survey or complete obstacle-avoidance result.
View comparison topicMass comes first, with host enclosure and integration
The approximately 10 g TFA170-L suits payload-sensitive long-range directional input with host-provided protection and power.
Boundary: Check RS-232, 12 V and the delivered version's output rate. Compare TF03 for an enclosure and other interface choices.
View model detailsOutdoor enclosure and multiple interface choices
Compare TF03 when about 86 g is acceptable and IP67 with a compatible interface is needed for a defined target direction.
Boundary: Check range and interface variants separately. If shorter-range models already meet the real distance, compare their lower mass too.
View model detailsHigh update rate with variant-specific enclosure choices
Compare TFA300 series for high-rate UAV or gimbal range input, choosing enclosure versus payload by hardware variant.
Boundary: Do not combine TFA300-L mass and range with TFA300 IP67 into one specification. Check output rate for the same variant.
View model detailsAdditional distance warrants a larger platform load
Compare TF350 when a fixed or larger platform needs more directional distance and can accept about 224 g and its mounting volume.
Boundary: Validate target size, optical-axis jitter and mounting rigidity for the narrow field. For shorter tasks, compare the system benefit of lighter models.
View model details| Parameter | TFA170-L | TF03 | TFA300 Series | TF350 |
|---|---|---|---|---|
| Measuring range | 0.1 ~ 170 m | 0.1 ~ 180 m | — | 0.2 ~ 350 m |
| Detecting accuracy | ± 10 cm (< 10 m), 1% (≥ 10 m) | ± 10 cm (≤ 10 m)1% (> 10 m) | ± 10 cm (<10 m)1% (≥ 10 m) | ± 10 cm (≤ 10 m)1% (> 10 m) |
| Frame rate | 1 ~ 1000 Hz | 1 ~ 9800 Hz | 1 ~ 10,000 Hz | 1 ~ 9800 Hz |
| Interface | RS-232 | UART,CAN,RS-232,RS-485 | UART,CAN | UART,CAN,RS-232,RS-485 |
| Protection | without enclosure | IP67 | — | IP67 |
| Dimensions | 31.0 mm × 30.2 mm × 19.2 mm | 44 mm × 43 mm × 32 mm | — | 78 mm × 67 mm × 40 mm |
| Power consumption | ≤ 1 W | ≤800 mW | ≤ 0.45 W | ≤ 1 W |
| Weight | ~ 10 g | 86 ± 3 g | — | 224 ± 3 g |
| Field of view | < 0.5° | 0.5° | < 0.5° | 0.35° |
| Operating voltage | DC 12 ± 10% V | 5 ~ 24 V | DC 5 V ± 10% | 5 ~ 24 V |
FAQ
What is the measurement range of the TF350?
The TF350 offers a range of 0.2–350m indoors (at 90% reflectivity) and 0.2–300m outdoors at 100Klux ambient light (at 90% reflectivity). At lower reflectivity (10%), the range is reduced to 0.2–110m indoors and 0.2–100m outdoors. This long-range capability makes it suitable for vehicle collision avoidance and traffic monitoring applications.
What communication interfaces does the TF350 support?
The TF350 offers multiple communication options: UART (3.3V LVTTL), CAN (1000 kbps standard frame), and switchable RS485/RS232 interfaces. All interfaces operate at a standard baud rate of 115200 for serial connections, with 8 data bits and 1 stop bit. This flexibility allows integration with diverse industrial control systems including PLCs, automotive ECUs, and embedded platforms.
Which tasks suit TF350, and why choose it?
Evaluate TF350 when industrial equipment must observe a distant target and benefits from an IP67 enclosure and compatible interfaces. It supplies directional spacing, trigger or long-range warning data.
What are the accuracy and precision specifications of the TF350?
The TF350 provides ±10cm accuracy within 10 meters, then 1% accuracy beyond 10 meters. Its distance resolution is 1cm with repeatability (1σ) of less than 3cm. These specifications are measured at 25°C with a 90% reflectivity white board, ensuring predictable performance for precision distance measurement in industrial applications.
What is the operating environment and environmental protection rating?
TF350 specifies -25°C to +60°C operation and IP67 enclosure protection. Compensation algorithms and ambient-light figures have test conditions; they do not establish unchanged range or performance in all rain, snow, fog and contamination. Outdoor projects should test target visibility, valid-return rate and window maintenance.
What power supply and current requirements does the TF350 have?
The TF350 accepts a wide supply voltage range of 5V–24V, with average current consumption of ≤150mA at 5V, ≤80mA at 12V, and ≤50mA at 24V. Total power consumption is ≤1W, making it energy-efficient for battery-powered platforms like UAVs and industrial IoT applications. This low power profile enables integration into resource-constrained systems.
What are the physical dimensions and weight of the TF350?
The TF350 measures 78mm (length) × 67mm (width) × 40mm (height) with a weight of 222g (standard version) or 225g (RS485 version, ±3g tolerance). Its compact aluminum alloy enclosure is designed for mounting on vehicles, drones, and industrial equipment. The 70cm cable length allows flexible installation in diverse mechanical configurations.
When should an alternative to TF350 be considered?
For shorter real working distances, compare lighter TF03 or TF02-Pro models. Micro-UAVs and compact gimbals should also compare lightweight modules by payload cost. More single-point range does not replace scanning or 3D coverage. Include approximately 224 g and the narrow field in mounting design. Validate usable distance with target size, reflectivity, aiming stability and actual weather. If the project requires functional-safety certification, verify the corresponding evidence separately; Class 1 laser eye safety is not functional-safety certification.
How should TF350 be compared with other models or sensing approaches?
Against TF03, ask whether added working distance warrants more mass and volume. Against kilometer-class light modules, also compare update rate, enclosure and power rather than judging only by range.
What platforms and systems integrate with the TF350?
The TF350 integrates with UART/CAN-capable platforms including Arduino, ROS-compatible robotics systems, PLC controllers, automotive ECUs, and custom embedded Linux systems. The RS485/RS232 variants enable integration with legacy industrial automation systems and Modbus-based networks. Standard 115200 baud rate serial communication and configurable CAN parameters (1000 kbps) support both real-time and non-real-time applications. Detailed integration instructions are provided in the user manual for custom firmware development.
Why might RS485 configuration commands not work on my sensor?
Confirm the model-specific protocol, baud rate, and interface first. A baud rate that is too low for the configured frame rate can overflow the transmit buffer. TF03 TTL/RS485/CAN commands must not be mixed with the Modbus commands for TFmini-i-485 or TF02-I-485; use the model manual.
How do I switch a TF03 between UART and CAN?
To switch UART to CAN, send 5A 05 45 02 A6 and then 5A 04 11 6F to save. To switch CAN to UART, send 5A 05 45 01 A5 over the CAN bus and save. Reconnect using the new interface and the 250 kbps CAN configuration.
How can I recover a sensor that became unresponsive after a high frame rate or low baud rate setting?
The transmit buffer may have overflowed. Use a Benewake offline downloader with the matching bin firmware and align its probes to the four-pin debug interface using the PCB GND mark. Get support guidance before doing this; in future, raise the baud rate and reconnect before raising the frame rate.
Why does a sensor return a constant 220–230 cm distance with no obstacle?
A nearby infrared source, such as a security camera illuminator, is a common cause. Capture 9-byte raw data including strength, temporarily disable or shield the suspected source, then add shielding, relocate the sensor, or revise the installation.